system_error_monitor#

Purpose#

Autoware Error Monitor has two main functions.

  1. It is to judge the system hazard level from the aggregated diagnostic information of each module of Autoware.
  2. It enables automatic recovery from the emergency state.

Inner-workings / Algorithms#

State Transition#

uml diagram

updateEmergencyHoldingCondition Flow Chart#

uml diagram

Inputs / Outputs#

Input#

Name Type Description
/diagnostics_agg diagnostic_msgs::msg::DiagnosticArray Diagnostic information aggregated based diagnostic_aggregator setting is used to
/autoware/state autoware_auto_system_msgs::msg::AutowareState Required to ignore error during Route, Planning and Finalizing.
/control/current_gate_mode tier4_control_msgs::msg::GateMode Required to select the appropriate module from autonomous_driving or external_control
/vehicle/control_mode autoware_auto_vehicle_msgs::msg::ControlModeReport Required to not hold emergency during manual driving

Output#

Name Type Description
/system/emergency/hazard_status autoware_auto_system_msgs::msg::HazardStatusStamped HazardStatus contains system hazard level, emergency hold status and failure details
/diagnostics_err diagnostic_msgs::msg::DiagnosticArray This has the same contents as HazardStatus. This is used for visualization

Parameters#

Node Parameters#

Name Type Default Value Explanation
ignore_missing_diagnostics bool false If this parameter is turned off, it will be ignored if required modules have not been received.
add_leaf_diagnostics bool true Required to use children diagnostics.
diag_timeout_sec double 1.0 (sec) If required diagnostic is not received for a diag_timeout_sec, the diagnostic state become STALE state.
data_ready_timeout double 30.0 If input topics required for system_error_monitor are not available for data_ready_timeout seconds, autoware_state will translate to emergency state.
data_heartbeat_timeout double 1.0 If input topics required for system_error_monitor are not no longer subscribed for data_heartbeat_timeout seconds, autoware_state will translate to emergency state.

Core Parameters#

Name Type Default Value Explanation
hazard_recovery_timeout double 5.0 The vehicle can recovery to normal driving if emergencies disappear during hazard_recovery_timeout.
use_emergency_hold bool false If it is false, the vehicle will return to normal as soon as emergencies disappear.
use_emergency_hold_in_manual_driving bool false If this parameter is turned off, emergencies will be ignored during manual driving.
emergency_hazard_level int 2 If hazard_level is more than emergency_hazard_level, autoware state will translate to emergency state

YAML format for system_error_monitor#

The parameter key should be filled with the hierarchical diagnostics output by diagnostic_aggregator. Parameters prefixed with required_modules.autonomous_driving are for autonomous driving. Parameters with the required_modules.remote_control prefix are for remote control. If the value is default, the default value will be set.

Key Type Default Value Explanation
required_modules.autonomous_driving.DIAGNOSTIC_NAME.sf_at string "none" Diagnostic level where it becomes Safe Fault. Available options are "none", "warn", "error".
required_modules.autonomous_driving.DIAGNOSTIC_NAME.lf_at string "warn" Diagnostic level where it becomes Latent Fault. Available options are "none", "warn", "error".
required_modules.autonomous_driving.DIAGNOSTIC_NAME.spf_at string "error" Diagnostic level where it becomes Single Point Fault. Available options are "none", "warn", "error".
required_modules.autonomous_driving.DIAGNOSTIC_NAME.auto_recovery string "true" Determines whether the system will automatically recover when it recovers from an error.
required_modules.remote_control.DIAGNOSTIC_NAME.sf_at string "none" Diagnostic level where it becomes Safe Fault. Available options are "none", "warn", "error".
required_modules.remote_control.DIAGNOSTIC_NAME.lf_at string "warn" Diagnostic level where it becomes Latent Fault. Available options are "none", "warn", "error".
required_modules.remote_control.DIAGNOSTIC_NAME.spf_at string "error" Diagnostic level where it becomes Single Point Fault. Available options are "none", "warn", "error".
required_modules.remote_control.DIAGNOSTIC_NAME.auto_recovery string "true" Determines whether the system will automatically recover when it recovers from an error.

Assumptions / Known limits#

TBD.