Functional Requirements — autoware_redundancy_switcher_interface#

1. Purpose#

This package provides the framework for managing redundancy switching in an Autoware-based vehicle system. It mediates between the Autoware stack (lower system) and a hardware Switcher (upper system) to decide when and how to transfer control authority between redundant ECUs.


2. Functional Requirements#

FR-01: System state aggregation#

The system shall continuously receive and maintain the following state from the Autoware stack:

Input Source Values
Autoware readiness /set_initializing service False / True
Vehicle velocity velocity topic Stopped / Moving
Vehicle control mode control mode topic Manual / Auto

Each state field shall be nullopt until the first message is received (startup not yet complete).


FR-02: Switcher state reception#

The system shall receive the switching state from a SwitcherAdapter plugin and represent it as three mutually exclusive boolean signals:

Signal Meaning
is_stable Switching is complete; self-interruption is possible
is_self_interrupted A self-interruption has been acknowledged; only reset is accepted
is_faulted An unrecoverable fault has been reported; all operations are rejected
all false Transitional state — startup or state change in progress

The SwitcherAdapter plugin is responsible for translating hardware-specific state into these three signals.


FR-03: Active control unit management#

The system shall maintain and publish the currently active control unit (ECU/VCU IDs).

When the switcher state transitions to is_self_interrupted or is_faulted, the active control unit shall be forced to empty regardless of what the SwitcherAdapter reports.


FR-04: Self-interruption#

The system shall support a self-interruption request from the Autoware stack. Self-interruption requests this ECU to voluntarily step down from active control.

Acceptance conditions (all must hold):

  1. autoware_ready = True
  2. control_mode = Auto
  3. Switcher data has been received (not nullopt)
  4. is_stable = true (not already interrupted or faulted, not transitional)

Rejection cases:

Condition Log level Reason
autoware_ready ≠ True Debug Autoware is not ready
control_mode ≠ Auto Debug Autoware is not in control
No switcher data Warn Startup not yet complete
is_self_interrupted Debug Already interrupted
is_faulted Error Switcher fault
Transitional Info Switcher in transitional state

FR-05: Reset#

The system shall support a reset request to restore normal operation after self-interruption.

Processing rules (evaluated in order):

Condition Result ResponseStatus
velocity = Moving Rejected (Ignored) NO_EFFECT
autoware_ready ≠ True (incl. nullopt) Accepted SUCCESS
No switcher data Rejected (Error) UNKNOWN
is_self_interrupted Accepted SUCCESS
is_stable Rejected (NotNecessary) SUCCESS (already stable)
is_faulted Rejected (Error) UNKNOWN
Transitional Rejected (Error) UNKNOWN

The result is returned synchronously to the caller (SubSystemAdapter) via ResetResultCommand.


FR-06: Diagnostics#

The system shall publish a diagnostic_updater item named redundancy_switcher_interface_status with hardware ID {main,sub}_ecu_redundancy_switcher_interface, reflecting the aggregated state of the four fields below.

Field (key) OK WARN ERROR
switcher_signals is_stable is_self_interrupted, transitional (before timeout), nullopt is_faulted, transitional (timeout exceeded)
autoware_ready False or True nullopt —
velocity_status Stopped or Moving nullopt —
control_mode Manual or Auto nullopt —

The overall summary level is the worst level across all four fields.

A transitional switcher state that persists longer than diag.transitional_timeout_milli (ms) shall be reported as ERROR.

See DESIGN.md Section 12 for the full level mapping and message format.


FR-07: Logging#

All state changes and decision outcomes shall be emitted as LogCommand with appropriate log levels:

  • Debug: Rejections due to expected/normal conditions
  • Info: State changes, acceptances
  • Warn: Unexpected but recoverable conditions
  • Error: Fault states, programming errors

FR-08: Plugin extensibility for Switcher#

The Switcher-side adapter shall be loaded as a pluginlib plugin at runtime. This decouples the core logic from hardware-specific UDS/topic-based switching protocols.

When is_redundant = false, no plugin is loaded and a permanently stable signal is injected instead.


FR-09: Non-redundant mode#

When is_redundant = false (single-ECU system), the switcher plugin shall not be loaded. The system shall behave as if the switcher is permanently stable:

  • Diagnostics: OK
  • Reset requests: SUCCESS (not necessary)

FR-10: Thread safety#

All concurrent access from multiple adapter threads shall be safe. The EventGateway shall serialize Processor state transitions using a mutex. CommandBus dispatch shall run outside the lock to prevent blocking during I/O operations in adapters.


3. Configuration Parameters#

Parameter Package Default Description
is_redundant interface true Enable redundant mode
is_main_ecu interface / plugin required ECU role (main/sub)
diag.transitional_timeout_milli interface 2000.0 Transitional state ERROR threshold (ms)
switcher_plugin interface (required if redundant) pluginlib class name

4. Non-functional Requirements#

  • Determinism: Given the same sequence of InputEvents, the Processor shall always produce the same OutputCommands and state.
  • No exception propagation: Processor::handle() shall not propagate exceptions; errors are expressed as OutputCommands.
  • ROS independence of core logic: Processor, EventGateway, and CommandBus shall have no ROS dependencies, enabling pure C++ unit tests.